Chemical components of welding wire (%)
| C | Mn | Si | Cr | Ni | Mo | P | S | Cu | |
| Range | ≤0.03 | 1.0-2.5 | ≤0.65 | 19.5~22.0 | 9.0~11.0 | ≤0.75 | ≤0.03 | ≤0.03 | ≤0.75 |
| Test | 0.015 | 2.0 | 0.50 | 20.2 | 9.80 | 0.10 | 0.013 | 0.009 | 0.16 |
Mechanical properties of deposited metal
| Tensile strength Rm (Mpa) | Elongation ratio (%) | |||||
| Test | 590 | 40 | ||||
Reference current (DC+)
| Diameter (mm) | φ0.8 | φ1.0 | φ1.2 | |||
| Welding Current (A) | 70~150 | 100~200 | 140~220 | |||
Precautions:
- Shielding gas: pay attention to the purity of shielding gas, it is recommended to keep the mixed ratio at Ar + 1~3% O₂.
- Gas flow: 20~25L/min.
- Dry extension length: 15~25min.
- The rust layer, moisture, oil stain, dust, etc on the welding part shall be clearly removed.
Welding Position: H, OH, HF, F, VD, VU